Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Chinese Journal of Gastrointestinal Surgery ; (12): 1196-1204, 2019.
Article in Chinese | WPRIM | ID: wpr-800473

ABSTRACT

Objective@#To systematically evaluate the diagnostic value of optical imaging combined with indocyanine green (ICG)-guided sentinel lymph node (SLN) biopsy in gastric cancer, and to identify potential factors that would influence diagnostic accuracy.@*Methods@#Study was carried out by searching the electronic database of PubMed, Embase, Medline, Web of Science, and the Cochrane Library with keywords as "gastric/stomach" and "cancer/carcinoma/tumor/tumour/adenocarcinoma/neoplasm" and "sentinel lymph node" and "near-infrared/NIR or fluorescent imaging" and "indocyanine green/ICG" . Literature inclusion criteria: (1) gastric cancer clinical stage was cT0-3; (2) clinical stage determined by at least 2 kinds of imaging modalities; (3) optical imaging (near-infrared or fluorescence imaging) combined with ICG-guided SLN biopsy; (4) prospective study to predict lymph node metastasis; (5) intraoperative or postoperative pathology for all lymph nodes removed; (6) patients number in the literature >10 cases. Exclusion criteria: (1) patients with a history of ICG allergy or chemoradiotherapy; (2) previous history of endoscopic mucosal resection or endoscopic submucosal dissection; (3) patients with a variety of gastrointestinal tumor; (4) case reports, conference abstracts, clinical guidelines, editorials, reviews, meta-analysis and correspondence letters; (5) in vitro or animal experiments; (6) insufficient diagnostic efficacy data. The meta-analysis was performed in the Stata12.0 software using the "bivariate mixed-effects model" combined with the "midas" command to pool the data. Information such as true positive value, false positive value, false negative value, and true negative value of each included articles were extracted. The literature quality assessment map was drawn to describe the overall quality of the articles; the heterogeneity analysis was performed with the forest map, with P<0.01 considered as statistical significance; the funnel plot was used to describe publication bias, with P<0.1 considered as statistically significant. Area under curve (AUC) of summary receiver operator characteristic (SROC) was used to describe the diagnostic accuracy and the AUC closer to 1 indicated higher diagnostic accuracy. If there was heterogeneity (I2>50%) among studies, regression analysis and subgroup analysis were performed. P<0.05 was considered as statistically significant.@*Results@#A total of 15 studies (1020 patients) were included. The optical imaging contained near-infrared (NIR) and fluorescent imaging (FI). The diagnostic value of optical imaging combined with ICG-guided SLN biopsy in gastric cancer was as follows: the pooled sensitivity (Sen) was 0.95 (95% CI: 0.82 to 0.99), specificity (Spe) was 1.00 (95% CI: 0.92 to 1.00), positive likelihood ratio (PLR) was 30.39 (95% CI: 9.14 to 101.06), negative likelihood ratio (NLR) was 0.05 (95% CI:0.01 to 0.20), diagnostic odds ratio (DOR) was 225.54 (95% CI: 88.81 to 572.77), AUC was 1.00 (95% CI: 0.99 to 1.00), threshold value was sensitivity=0.95 (95% CI: 0.82 to 0.99) and specificity=1.00 (95% CI: 0.92 to 1.00). Deeks method revealed DOR funnel plot of SLN biopsy was not asymmetrical obviously with significant difference (P=0.01), which indicated remarkable publishing bias. Meta-subgroup analysis showed that compared to FI, NIR imaging had higher sensitivity (0.98 vs. 0.73); compared to 0 minutes, optical imaging performed 20 minutes after ICG injection had higher sensitivity (0.98 vs. 0.70); compared to mean detected number of SLN of 4, mean detected number≥4 had higher sensitivity (0.96 vs. 0.68); compared to HE stain, immunohistochemistry + HE had higher sensitivity (0.99 vs. 0.84); compared to subserous injection of ICG, submucosa injection of ICG had higher sensitivity (0.98 vs. 0.40); compared to injection of 5 g/L ICG, 0.5 g/L and 0.05 g/L had higher sensitivity (0.98 vs. 0.83); compared to cT2-3 tumor, early stage (cT1) tumor had higher sensitivity (0.96 vs. 0.72); compared to ≤ enrolled 26 cases in the study, > 26 cases had higher sensitivity (0.96 vs. 0.65); compared to papers before 2010, papers after 2010 had higher sensitivity (0.97 vs. 0.81); whose differences were all significant. Sensitivity differences between mean tumor diameter of ≤30 cm and >30 cm, open surgery and laparoscopic surgery, lymph node regional dissection and retrieved dissection were not significant (all P>0.05).@*Conclusions@#Optical imaging combined with ICG-guided SLN biopsy is clinically feasible, and especially suitable for early gastric cancer. However, the ICG being used in current studies may be overdosed. Higher sensitivity may be achieved from NIR imaging when compared with FI method.

2.
International Journal of Surgery ; (12): 841-847, 2017.
Article in Chinese | WPRIM | ID: wpr-693187

ABSTRACT

Objective To evaluate the surgical effect of laparoscopic anterior resection of rectal carcinoma with or without the left colic artery.Methods Through computer searching PubMed,Cochrane Library,Embase,WanFang Date and CNIK Date.Handsearching the Gray literature simultaneously.The randomized controlled trails and clinical controlled trials comparing low ligation with high ligation the inferior mesenteric artery in laparoscopic anterior resection of rectal carcinoma were colected.Data were screened,extracted and evaluated by two reviewers independently.Meta-analyses were conducted using the sofeware STATE12.0.The standardized mean difference were calculated for continuous data and odds ratio for dichotomous and the point estimates of each effect quantity and 95% confidence interval were calculated.TheI2 test was used to test the heterogeneity of the inchuded literature:if the heterogeneity was small,the fixed effects model was adopted.otherwise,the random effects models was adopted and explored the heterogeneity by sensitivity analysis or subgroup analysis.Results Forteen articles including 15 researches were met the selection criteria.The Meta-analyses showed that the grope of low ligation had lower rate of anastomotic fistula (OR =0.394,95 % CI:0.251-0.616,P =0.000) and longer opration time (SMD =0.361,95%CI:0.242-0.480,P =0.000).There is no statistical differences in the number of lymph node dissection besides the root of IMA (SMD =-0.017,95% CI:-0.130-0.097,P =0.772) intraoperative biood loss (SMD =0.083,95 % CI:-0.048-0.214,P =0.213).Conclusions In spite of reserved the left colic artery had longer operation time it can reducedrate of anastomotic fistula effectively and there is no statistical differences in the number of lymph node dissection besides the root of IMA,intraoperative blood loss.It is possible to promote the use of reserved the left colic artery in laparoscopic anterior resection of rectal carcinoma.

3.
China Pharmacy ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-527823

ABSTRACT

OBJECTIVE:To provide suggestions for the improvement of eye drops specifications(EDS)so as to promote safe and effective use of eye drops.METHOD:123kinds of EDS in18categories in our hospital pharmacy were investigated and analyzed.RESULTS:Several important contents in the specifications like pharmacology and toxicology,pharmacokinetics,ad-verse reactions,contraindications,precautions,medications for pregnant and nursing women,and that for children and senile patients,drug interactions and overdose failed to fully meet the national criteria.The quality of the imported EDS was superior to that of the domestic EDS.CONCLUSIONS:The EDS were still far from being perfect and improvement of which is neces-sary so that more detailed drug information is available for physicians,pharmacists and patients,which is conducive to safe and effective use of drugs.

4.
China Pharmacy ; (12)1991.
Article in Chinese | WPRIM | ID: wpr-521971

ABSTRACT

OBJECTIVE:To observe the stability of phacolin eye drops.METHODS:The content and the stability of phacolin eye drops were determined by ultraviolet spectrophotometry and the initial average rate method respectively.RESULTS:The activation energy for pyrolytic reaction of phcolin eye drops was25.681kcal/mol,the shelflife of phacolin eye drops at room temperature(25℃)and10℃were88and878days respectively.CONCLUSION:The determination of the stability of phacolin eye drops with initial average rate method is useful and simple.

SELECTION OF CITATIONS
SEARCH DETAIL